39 stac6 hardware manual – Applied Motion STAC6-C User Manual
Page 39
39
STAC6 Hardware manual
920-0029 Rev. C
5/2/2012
Connecting another Si Drive
IN/OUT2
IN
COM
Si354, 7080i etc
OUT+
OUT–
12-24
VDC
Power
Supply
-
+
(When output closes, drive input goes low).
Connecting an NPN Type Proximity Sensor to an input
IN/OUT2
NPN
Proximity
Sensor
IN
COM
output
+
–
12-24
VDC
Power
Supply
-
+
(When prox sensor activates, drive input goes low).
Connecting a PNP Type Proximity Sensor to an input
IN/OUT2
PNP
Proximity
Sensor
IN
output
+
–
COM
12-24
VDC
Power
Supply
-
+
(When prox sensor activates, drive input goes low).