Chapter 6: Board Test System
6–19
Using the Board Test System
July 2012
Altera Corporation
Transceiver Signal Integrity Development Kit
Stratix V GX Edition User Guide
Error Control
This control displays data errors detected during analysis and allows you to insert
errors:
■
Detected errors
—Displays the number of data errors detected in the hardware.
■
Inserted errors
—Displays the number of errors inserted into the transmit data
stream.
■
Insert Error
—Inserts a one-word error into the transmit data stream each time you
click the button. Insert Error is only enabled during transaction performance
analysis.
■
Clear
—Resets the Detected errors and Inserted errors counters to zeros.
Loopback
■
TX
and RX performance bars—Show the percentage of maximum theoretical data
rate that the requested transactions are able to achieve.
■
Start
—This control initiates the loopback tests.
■
Stop
—This control terminates the loopback tests.
■
Tx (MBps)
and Rx (MBps)—Show the number of bytes of data analyzed per
second.