3–20
Altera
Corporation
PowerPlay Early Power Estimator For Stratix II, Stratix II GX & HardCopy II
January 2007
PowerPlay Early Power Estimator Inputs
Table 3–5
describes the I/O bank parameters in the I/O section of the
PowerPlay Early Power Estimator.
Figure 3–11
shows how the V
CCIO
level is listed for each I/O bank. The
PowerPlay Early Power Estimator spreadsheet shows the I
CCIO
listed for
each bank. Select the V
CCIO
voltage in the V
CCIO
column.
Figure 3–11. V
CCIO
Listed for Each I/O Bank
Table 3–6
describes the I/O module parameters in the I/O section of the
PowerPlay Early Power Estimator.
Table 3–5. I/O Bank Information in the I/O Section
Column Heading
Description
V
CCI O
Select the V
CCI O
voltage for each bank. Used to cross-check selected I/O standards
in table below for warning purposes.
I
CCI O
(A)
This shows the total supply current due to the I/O pins in each I/O bank. This may be
higher than the thermal power due to current supplied to off-chip termination resistors.
Unassigned
This represents the I
CCI O
of all I/O modules not assigned to an I/O bank.
Table 3–6. I/O Module Information in the I/O Section (Part 1 of 3)
Column Heading
Description
Module
Enter a name for the module in this column. This is an optional value.
I/O Standard
Select the I/O standard used for the input, output or bidirectional pins in this module
from the list. The calculated I/O power varies based on the I/O standard.
Drive Strength/ On-chip
Termination
Select the drive strength or on-chip termination implemented for the I/O pin(s) in this
module. Drive strength and on-chip termination are mutually exclusive.