Chapter 5: Board Test System

5–11

Using the Board Test System

November 2013

Altera Corporation

Cyclone V SoC Development Kit

User Guide

Pattern Generator

This control specifies the test pattern to output to the monitor. The following choices
are available:

Pattern

Color bar

—Specifies a video color bar pattern with eight vertical color bars as

shown in table

Table 5–1

.

Pathological

—Specifies a video color bar pattern with two horizontal color bars

that stresses the receive PLL.

PRBS

—Specifies a pseudo-random bit sequence useful for electrical testing of the

interface for data integrity.

Intensity

Specifies the color intensity of the transmitted color bar pattern. The following choices
are available.

75%

—Specifies 75% intensity.

100%

—Specifies 100% intensity.

SDI Standard

Specifies the video standard used by the pattern generator on the SDI video stream.
The following choices are available:

SD

—Specifies a 270 Mbps data rate.

HD

—Specifies a 1.485 Gbps data rate.

3G HD

—Specifies a 2.97 Gbps data rate.

Clock Source

Specifies the clock used by the SDI PLL to lock onto. The following choices are
available:

Lock to host

—Locks the SDI PLL to the local reference on the Cyclone V SoC

Development board.

Lock to input

—Locks the SDI PLL to the SDI video data input.

Table 5–1. HDMI Color Bar Test Pattern

Color Bars

Color

RGB Values

White/Grey

180,180,180

Yellow

180,180,16

Cyan

16,180,180

Green

16,180,16

Magenta

180,16,180

Red

180,16,16

Blue

16,16,180

Black

16,16,16