Altera Remote Update IP Core User Manual
Page 36

read_
para
m
write
_
para
m
read_source param
Remote Update Operation
data_out
width
(bits)
MSM Mode
1
0
[00]
[000] Master State Machine Current State Mode
(Read Only)
• 00—Factory mode
• 01—Application mode
• 11—Application mode with Master State
Machine User Watchdog Timer Enabled
2
Factory or
Application
1
0
[00]
[100] Read factory boot address
24
Factory
1
0
[01]
[100] Read Past Status 1 boot address.
For more information, refer to
24
Factory
1
0
[01]
[111] Read Past Status 1 reconfiguration trigger
condition source.
For more information, refer to
5
Factory
1
0
[10]
[100] Read Past Status 2 boot address.
For more information, refer to
24
Factory
1
0
[10]
[111] Read Past Status 2 reconfiguration trigger
condition source
For more information, refer to
5
Factory
1
0
[01]
[010] Read current application mode watchdog
value
29
Application
1
0
[01]
[011] Read current application mode watchdog
enable
1
Application
1
0
[10]
[100] Read current application mode boot address
24
Application
0
1
[00]
[001] Write the early
confdone
check bit.
All parameters can be written in factory
mode only.
1
Factory
0
1
[00]
[010] Write the watchdog time-out value.
All parameters can be written in factory
mode only.
12
Factory
36
Remote Update Operation
UG-31005
2015.04.07
Altera Corporation
Altera Remote Update IP Core User Guide