Ports – Altera Remote Update IP Core User Manual
Page 28

GUI Name
Legal Value in GUI
Description
Which configuration
device will you be using?
•
EPCS device
•
EPCQ device
Choose the configuration device that you are using.
Add support for writing
configuration parameters
—
Enable this if you need to write configuration
parameters.
Enable reconfig POF
checking
—
Allows you to enable .pof checking, which allows the
remote update block to verify the existence of an
application configuration image before the image is
loaded. When you turn on this parameter, the Altera
Remote Update IP core checks the .pof and sends the
reconfig
signal. This option is disabled by default.
Ports
Table 12: Altera Remote Update IP Core Ports for Cyclone IV Devices
Name
Port
Required
?
Description
read_param
Input
No
Read signal for the parameter specified in
param[]
input port and fed to
data_out[]
output port.
Signal indicating the parameter specified on the
param[]
port should be read. The number of bits
set on
data_out[]
depends on the parameter
type. The signal is sampled at the rising clock
edge. Assert the signal for only one clock cycle to
prevent the parameter from being read again in a
subsequent clock cycle.
The busy signal is activated as soon as
read_
param
is read as active. While the parameter is
being read, the busy signal remains asserted, and
data_out[]
has invalid data. When the busy
signal is deactivated,
data_out[]
is valid,
another parameter can be read.
28
Ports
UG-31005
2015.04.07
Altera Corporation
Altera Remote Update IP Core User Guide