Altera Remote Update IP Core User Manual
Page 33

Name
Port
Required
?
Description
asmi_dataout
Input
No
Input from the
altasmi_parallel
component.
Available when the
check_app_pof
parameter is
set to
true
.
The Altera Remote Update IP core presents the
address information on this pin before initiating
the read operation on the ALTASMI_
PARALLEL IP core.
pof_error
Output
No
Detects and invalid application configuration
image.
Available when the
check_app_pof
parameter is
set to TRUE.
A logic high on this pin indicates that the Altera
Remote Update IP core detects an invalid
application configuration image. If asserted high,
you must take corrective action by reloading a
new application configuration image or
specifying a different address location in the
EPCS or EPCQ that contains a valid application
configuration image. Wire this pin based on your
system requirement.
asmi_addr
Output
No
Address signal to
altasmi_parallel
component.
Available when the
check_app_pof
parameter is
set to TRUE. The Altera Remote Update IP core
presents the address information on this pin
before initiating the read operation on the
ALTASMI_PARALLEL IP core.
Wire this pin to the
asmi_addr
input port of the
ALTASMI_PARALLEL IP core.
asmi_read
Output
No
Read signal to
altasmi_parallel
component.
Available when the
check_app_pof
parameter is
set to TRUE. A logic high on this pin initiates the
read operation on the ALTASMI_PARALLEL IP
core.
Wire this pin to the
asmi_read
input port of the
ALTASMI_PARALLEL IP core.
UG-31005
2015.04.07
Ports
33
Altera Remote Update IP Core User Guide
Altera Corporation