beautypg.com

Pilz PSSu E F PS2 User Manual

Page 27

background image

Technical details

Operating Manual PSSu E F PS2(­T)(­R)
1002237­EN­03

27

Electrical data

312192

314192

315192

Internal supply voltage
(module supply)

Output voltage

int. system

int. system

int. system

Voltage

5 V

5 V

5 V

Voltage tolerance

­2 %/+3 %

­2 %/+3 %

­2 %/+3 %

Module's current con­
sumption

40 mA

40 mA

40 mA

Module's power con­
sumption

0,20 W

0,20 W

0,20 W

Potential isolation

3050 V

3050 V

3050 V

Current load capacity

1,0 A

1,0 A

1,0 A

Buffer in the case of
supply interruptions in
accordance with

DIN V EN V 1954, EN
61131­2, EN 61496­1

DIN V EN V 1954, EN
61131­2, EN 61496­1

DIN V EN V 1954, EN
61131­2, EN 61496­1

Short circuit­proof

Yes

Yes

Yes

Periphery's supply voltage
(periphery supply)

Module's current con­
sumption with no load

5 mA

5 mA

5 mA

Module's power con­
sumption with no load

0,12 W

0,12 W

0,12 W

Max. power dissipation of
module

2,00 W

2,00 W

2,00 W

Environmental data

312192

314192

315192

Application site

In accordance with the
standard

EN 50125­3

Application site

Track area (1 m ­ 3 m)

In accordance with the
standard

EN 61373

Application site

Category 1, Class A + B

Climatic suitability

EN 60068­2­1, EN
60068­2­14, EN
60068­2­2, EN
60068­2­30, EN
60068­2­78

EN 60068­2­1, EN
60068­2­14, EN
60068­2­2, EN
60068­2­30, EN
60068­2­78

EN 50155, EN 60068­2­1,
EN 60068­2­14, EN
60068­2­2, EN
60068­2­30, EN
60068­2­78

Ambient temperature

In accordance with the
standard

EN 50155

Temperature range

0 ­ 60 °C

­40 ­ 70 °C

­40 ­ 70 °C

In accordance with the
standard

EN 50125­1

Temperature range

­40 ... +70 °C

In accordance with the
standard

EN 50125­3

Temperature range

­40 ... +70 °C

Storage temperature

Temperature range

­25 ­ 70 °C

­40 ­ 70 °C

This manual is related to the following products: