beautypg.com

2 removing an electronic module, 3 changing an electronic module during operation, Removing an electronic module – Pilz PSSu E S 4DO 0.5-D User Manual

Page 19: Changing an electronic module during operation

background image

Installation

Operating Manual PSSu E S 4DO 0.5-(T)D
21951-EN-06

19

Removing an electronic module

Procedure:

}

Press the locking mechanisms [1] together simultaneously.

}

Pull out the electronic module [2].

Schematic representation:

[1]

[2]

[1]

Changing an electronic module during operation

The electronic module can be hot swapped. The configuration data is retained when a mod-
ule is swapped.
Effects:

}

System environment A:

– An ST communication error may occur.

}

System environment B:

– While the module is disconnected, the substitute values for the module's signals/

values are used (Valid Bits = FALSE).

– Once the module is reconnected, it is reactivated automatically.

ATTENTION!
Sparking can cause interference and errors!
Only change the module when the load is switched off!

5.3.2

5.3.3

This manual is related to the following products: