background image

Technical details

Operating Manual PSSu E F 2DI 60­R
1002506­EN­02

26

8

Technical details

General

315201

Approvals

CE, TÜV, cULus Listed

Application area

Failsafe

Module's device code

0A01h

Application in system environment B

From FS firmware version, head modules

1.5.0

Electrical data

315201

Internal supply voltage (module supply)

Supply voltage range of module supply

4,8 ­ 5,4 V

Module's current consumption

23 mA

Module's power consumption

0,12 W

Max. power dissipation of module

1,50 W

Inputs

315201

Number

2

Voltage at inputs

24 ­ 72 V

Input current range

1,5 ­ 8,5 mA

Min. threshold voltage when signal changes from "1"
to "0"

5,0 V

Max. threshold voltage when signal changes from "0"
to "1"

19,2 V

Potential isolation between input and voltage for the
internal module bus

Yes

Environmental data

315201

Application site

In accordance with the standard

EN 50125­3

Application site

Track area (1 m ­ 3 m)

In accordance with the standard

EN 61373

Application site

Category 1, Class A + B

Climatic suitability

EN 50125­1, EN 50125­3, EN 50155, EN 60068­2­1,
EN 60068­2­14, EN 60068­2­2

Ambient temperature

In accordance with the standard

EN 50155

Temperature range

­40 ­ 70 °C

In accordance with the standard

EN 50125­1

Temperature range

­40 ... +70 °C

In accordance with the standard

EN 50125­3

Temperature range

­40 ... +70 °C

Storage temperature

In accordance with the standard

EN 60068­2­1/­2

Temperature range

­40 ­ 70 °C

Climatic suitability

In accordance with the standard

EN 60068­2­78

Humidity

93 % r. h. at 40 °C

Condensation during operation

Short­term