2 integrated protection mechanisms, 2 configuration, 1 converter characteristics/default value – Pilz PSSu E F AI I User Manual
Page 14: Integrated protection mechanisms, Configuration, Converter characteristics/default value
![background image](https://www.manualsdir.com/files/762726/content/doc014.png)
Function description
Operating Manual PSSu E F AI I(T)(R)
21981EN05
14
WARNING!
Limit values selected in the user program too low or too high!
Risk of serious injury and death!
– Take into account the max. safetyrelated accuracy when defining
the limit values in the user program.
}
For safe resolution up to 256 levels you will need to use two analogue inputs and to
carry out a feasibility test.
}
With 2channel mode, the achievable safetyrelated accuracy will depend on the mod
ule's measuring accuracy and sensors.
}
The module's measuring accuracy is calculated by adding all deviations from the meas
uring range limit value (see chapter entitled "Technical Details"). With 2channel, di
verse operation, this value is doubled in the worst case.
Illustration of the resolution ranges:
2 4 8 16 32 64 128 256 512 1024 2048 4096
0 1 2 3 4 5 6 7 8 9 10 11
Bit
Resolution
Safe (1 analogue input)
Safe (2 analogue inputs)
Standard
MSB
LSB
4.1.2
Integrated protection mechanisms
When the PSSu E F PS1(T) is used to supply the system, the module supply is buffered
for 20 ms if the supply voltage is interrupted.
The module detects the following errors:
}
Startup error
}
Configuration error
}
FS communication error
}
Bus termination error
4.2
Configuration
4.2.1
Converter characteristics/default value
The table below shows the converted data formats of the analogue input currents. When
the digital values are converted into I/O data elements, the three highest binary digits are
filled with "0".