External communication 312070

314070

315070

EtherNet/IP Adapter

Cycle time (tExtCom)

4...655 000 ms

4...655 000 ms

4...655 000 ms

Manufacturer’s ID

181

181

181

Product ID

1

1

1

EDS file

00B5000C00010100.eds 00B5000C00010100.eds 00B5000C00010100.eds

Unit type

Adapter

Adapter

Adapter

Cycle time (RPI)

4...655 000 ms

4...655 000 ms

4...655 000 ms

Maximum data length

508 Byte

508 Byte

508 Byte

Maximum number of I/
O connections

1

1

1

Raw UDP

Memory size

8 Kbyte

8 Kbyte

8 Kbyte

Cycle time (t_ExtCo)

2...2 000 000 ms

2...2 000 000 ms

2...2 000 000 ms

SafetyNET p interface

312070

314070

315070

Number

2

2

2

IP address (automatically
off)

169.254.X.Y

169.254.X.Y

169.254.X.Y

Connection

RJ45

RJ45

RJ45

Transmission rates

100 MBit/s

100 MBit/s

100 MBit/s

Set via

automatic

automatic

automatic

Max. number of ST­Tx
and ST­Rx connections

64

64

64

Max. number of FS­Tx
and FS­Rx connections

64

64

64

Cycle time (t_SNp)

2...60 000 ms

2...60 000 ms

2...60 000 ms

Max. number of variables
with elementary ST data
types

5000

5000

5000

Max. number of variables
with elementary FS data
types

4000

4000

4000

Environmental data

312070

314070

315070

Application site

In accordance with the
standard

EN 50125­3

Application site

Track area (1 m ­ 3 m)

In accordance with the
standard

EN 61373

Application site

Category 1, Class A + B

Climatic suitability

EN 60068­2­1, EN
60068­2­14, EN
60068­2­2, EN
60068­2­30, EN
60068­2­78

EN 60068­2­1, EN
60068­2­14, EN
60068­2­2, EN
60068­2­30, EN
60068­2­78

EN 50155, EN 60068­2­1,
EN 60068­2­14, EN
60068­2­2, EN
60068­2­30, EN
60068­2­78