4.1

Device properties

4

Function description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-2

Linking several decentralised modules:

A maximum of 4 link modules can be connected to a base unit

PNOZmulti Mini.

A maximum of 4 decentralised modules can be connected to a link

module PNOZ mml2p.

If a decentralised module receives data intended for a different

decentralised module that is connected, the data is forwarded

without being processed.

4.1.2.2

Block diagram

Block diagram

4-

Blockschaltbild PNOZ mml2p

24V 24V

=

Power

=

0V 0V

Interface to pr

evious

module

Interface to next module

CAN+ CAN-VCC GND FE