14
Service life graph
The service life graphs indicate the number of cycles from which failures due to wear must
be expected. The wear is mainly caused by the electrical load; the mechanical load is negli
gible.
Example
}
Inductive load: 0,2 A
}
Utilisation category: AC15
}
Contact service life: 2,000,000 cycles
Provided the application requires fewer than 2,000,000 cycles, the PFH value (see tech
nical details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output
contacts. With capacitive loads, any power surges that occur must be noted. With contact
ors, use freewheel diodes for spark suppression.
Order reference
Type
Features
Terminals
Order no.
PNOZ c1
24 VDC
With springloaded terminals
710 001
EC Declaration of Conformity
This product/these products meet the requirements of the directive 2006/42/EC for ma
chinery of the European Parliament and of the Council. The complete EC Declaration of
Conformity is available on the Internet at www.pilz.com/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, FelixWankelStr. 2, 73760 Ost
fildern, Germany