Pilz PNOZ c1 24VDC 3n/o 1n/c User Manual
Page 10

PNOZ c1
Operating Manual PNOZ c1
22197EN02
10
Electrical data
710001
Max. inrush current impulse
Current pulse, A1
1,80 A
Pulse duration, A1
4,0000 ms
Current pulse, input circuit
0,35 A
Pulse duration, input circuit
25,0 ms
Current pulse, feedback loop
0,15 A
Pulse duration, feedback loop
2,0 ms
Current pulse, start circuit
0,15 A
Pulse duration, start circuit
2,0 ms
Max. overall cable resistance Rlmax
Dualchannel with detection of shorts across con
tacts at UB DC
15 Ohm
Min. input resistance at poweron
88 Ohm
Voltage at
Input circuit DC
24,0 V
Reset circuit DC
24,0 V
Feedback loop DC
24,0 V
Current at
Input circuit DC
30,0 mA
Reset circuit DC
40,0 mA
Feedback loop
40,0 mA
Number of output contacts
Instantaneous safety contacts (N/O)
3
Auxiliary contacts (N/C)
1
Inputs
710001
Number
2
Relay outputs
710001
Max. short circuit current IK
1 kA
Utilisation category
In accordance with the standard
EN 6094741
Auxiliary contacts, AC1 at
240 V
Min. current
0,01 A
Max. current
6,0 A
Max. power
1500 VA
Auxiliary contacts, DC1 at
24 V
Min. current
0,01 A
Max. current
6,0 A
Max. power
150 W
Safety contacts, AC1 at
240 V
Max. current
6,0 A
Min. current
0,01 A
Max. power
1500 VA
Safety contacts, DC1 at
24 V
Max. current
6,0 A
Min. current
0,01 A
Max. power
150 W