beautypg.com

Safety characteristic data, Supplementary data, Service life graph – Pilz PZE X4P 24VDC 4n/o User Manual

Page 12

background image

PZE X4P

Operating Manual PZE X4P
1003201­EN­08

12

Mechanical data

777585

787585

Dimensions

Height

94,0 mm

101,0 mm

Width

22,5 mm

22,5 mm

Depth

121,0 mm

121,0 mm

Weight

175 g

175 g

The standards current on 2009­12 apply.

Safety characteristic data

Operating
mode

EN ISO
13849­1:
2008

PL

EN ISO
13849­1:
2008

Category

EN IEC
62061

SIL CL

EN IEC
62061

PFH

D

 [1/h]

IEC 61511

SIL

IEC 61511

PFD

EN ISO
13849­1:
2008

T

M

 [year]

PL e

Cat. 4

SIL CL 3

2,31E­09

SIL 3

2,03E­06

20

All the units used within a safety function must be considered when calculating the safety
characteristic data.

INFORMATION

A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.

Supplementary data

CAUTION!

It is essential to consider the relay's service life graphs. The relay outputs'
safety­related characteristic data is only valid if the values in the service life
graphs are met.

The PFH value depends on the switching frequency and the load on the relay output. If the
service life graphs are not accessible, the stated PFH value can be used irrespective of the
switching frequency and the load, as the PFH value already considers the relay's B10d
value as well as the failure rates of the other components.

Service life graph

The service life graphs indicate the number of cycles from which failures due to wear must
be expected. The wear is mainly caused by the electrical load; the mechanical load is negli­
gible.