beautypg.com

Pilz PZE X4P 24VDC 4n/o User Manual

Page 10

background image

PZE X4P

Operating Manual PZE X4P
1003201­EN­08

10

Relay outputs

777585

787585

Utilisation category

In accordance with the standard EN 60947­5­1

EN 60947­5­1

Safety contacts, AC15 at

230 V

230 V

Max. current

5,0 A

5,0 A

Safety contacts DC13 (6 cycles/
min) at

24 V

24 V

Max. current

5,0 A

5,0 A

Utilisation category in accordance
with UL

Voltage

240 V AC G.U. (same polarity)

240 V AC G.U. (same polarity)

With current

6,0 A

6,0 A

Voltage

24 V DC G. U.

24 V DC G. U.

With current

6,0 A

6,0 A

Pilot Duty

R300

R300

Contact fuse protection external,
safety contacts

In accordance with the standard EN 60947­5­1

EN 60947­5­1

Max. melting integral

260 A²s

260 A²s

Blow­out fuse, quick

10 A

10 A

Blow­out fuse, slow

6,00 A

6,00 A

Blow­out fuse, gG

10 A

10 A

Circuit breaker, 24V AC/DC,
characteristic B/C

6 A

6 A

Contact material

AgCuNi + 0,2 µm Au

AgCuNi + 0,2 µm Au

Conventional thermal current
while loading several contacts

777585

787585

Ith per contact at UB DC

Conv. therm. current with 1 con­
tact

6,00 A

6,00 A

Conv. therm. current with 2 con­
tacts

6,00 A

6,00 A

Conv. therm. current with 3 con­
tacts

5,00 A

5,00 A

Conv. therm. current with 4 con­
tacts

4,00 A

4,00 A

Times

777585

787585

Switch­on delay

With automatic start after power
on typ.

30 ms

30 ms

With automatic start after power
on max.

50 ms

50 ms

Delay­on de­energisation

With E­STOP typ.

30 ms

30 ms

With E­STOP max.

50 ms

50 ms

With power failure typ.

30 ms

30 ms

With power failure max.

50 ms

50 ms

Supply interruption before de­ener­
gisation

20 ms

20 ms