Blower performance data, Setting blower speed - variable speed ecm, Variable speed ecm blower motor – WaterFurnace 7 Series User Manual

Page 16: Variable speed ecm setup without an aid tool, Variable speed ecm setup with an aid tool

background image

16

7 SERIES 50Hz 700A11 INSTALLATION MANUAL

ECM Speed Info

1

2

◀ G

3

4

5

6

7

8

9

10

11

12

Option ◀▶

Enter ◙

ECM Speed Info

1

2

G

3

◀ Lo

4

5

6

7

8

9

10

11

12

Option ◀▶

Enter ◙

ECM Speed Info

1

2

G

3

Lo

4

5

6

◀ Hi

7

8

9

10

11

12

Option ◀▶

Enter ◙

ECM Speed Info

1

2

G

3

Lo

4

5

6

Hi

7

8

9

▶10

◀ Aux

11

12

Option ◀▶

Enter ◙

ECM Speed Info

Blower Only Speed

3

Lo Compressor

6

Hi Compressor

9

Aux Heat

10

Want To Change?

Yes

Option ◀▶

No

Enter ◙

Cooling Airflow Setup

--- ECM Only ---

The airflow will be

adjusted by the chosen

amount in cooling mode.

Adjustment:

-15%

Want To Change?

Yes

Option ◀▶

No

Enter ◙

Cooling Airflow Setup

--- ECM Only ---

The airflow will be

adjusted by the chosen

amount in cooling mode.

Adjustment:

-15%

Change

▼▲

Enter ◙

Setting Blower Speed - Variable speed ECM

The ABC board’s Yellow Config LED will flash the current
ECM blower speed selections for G, low, and high
continuously with a short pause in between. The speeds
can also be confirmed with the AID Tool under the Setup/
ECM Setup screen. The Aux will not be flashed but can be
viewed in the AID Tool. The ECM blower motor speeds can
be field adjusted with or without using an AID Tool.

Variable speed ECM Setup without an AID Tool

The blower speeds for G only, Low (Y1), and High (Y2/
Aux) can be adjusted directly at the Aurora ABC board
which utilizes the push button (SW1) on the ABC board.
This procedure is outlined in the ECM Configuration Mode
portion of the Aurora ‘Base’ Control System section. The
Aux cannot be set manually without an AID Tool.

Variable speed ECM Setup with an AID Tool

A much easier method utilizes the AID Tool to change
the airflow using the procedure below. First navigate to
the Setup screen and then select ECM Setup. This screen
displays the current ECM settings. It allows the technician to
enter the setup screens to change the ECM settings. Change

the highlighted item using the

and

► buttons and then press the

◙ button to select the item.

Selecting YES will enter ECM
speed setup, while selecting NO
will return to the previous screen.

ECM Speed Setup - These screens allow the technician to
select the G, low, high, and auxiliary heat blower speed for
the ECM blower motor. Change the highlighted item using
the

▲ and ▼ buttons. Press the ◙ button to select the speed.

After the auxiliary heat speed setting is selected the AID
Tool will automatically transfer back to the ECM Setup screen.

Cooling Airflow Setup - These screens allow the technician
to select -15%, -10%, -5%, None or +5% change from the
heating airflow. Change the adjustment percentage using
the

▲ and ▼ buttons. Press the ◙ button to save the change.

Variable Speed ECM Blower Motor

Model

Air Flow

Max ESP

(Pa)

Speed 1

Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12

009

124.50

135

179

G

248

L

319

385

463

519

576

628

680

H

727

Aux

743

009 w/746W*

186.75

227

267

G

314

L

359

411

472

519

566

614

665

H

717

Aux

769

012

186.75

224

293

G

345

L

401

481

538

599

661

717

779

H

845
Aux

908

015

186.75

189

283

G

392

L

496

580

661

736

802

883

949

H

1010

Aux

1069

**VS Compressor Speed

1-2

3-4

5-6

7-8

9-10

11-12

** VS Compressor speed is given for the factory default L/s settings. When the L/s default settings are changed it will change the
relationship to the compressor speed that is shown in the table. In cooling mode compressor speeds 10-12 are only available when
SuperBoost mode is selected at the thermostat.
* Optional 746W Variable Speed ECM
Factory settings are at recommended L , H and Aux positions
“G” may be located anywhere within the airflow table
“L” setting should be located within the boldface L/s range
“H” setting MUST be located within the shaded L/s range
“Aux” setting MUST be equal to or greater than “H” setting
“Aux” setting MUST be equal to or greater than the minimum allowable L/s for the auxiliary heater kit (see auxiliary heat ratings table)
Cfm is controlled within 5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter

5/13/13

Blower Performance Data