Blower performance data, Setting blower speed - variable speed ecm, Variable speed ecm blower motor – WaterFurnace 7 Series User Manual
Page 16: Variable speed ecm setup without an aid tool, Variable speed ecm setup with an aid tool
16
7 SERIES 50Hz 700A11 INSTALLATION MANUAL
ECM Speed Info
1
▶
2
◀ G
3
4
5
6
7
8
9
10
11
12
Option ◀▶
Enter ◙
ECM Speed Info
1
2
G
▶
3
◀ Lo
4
5
6
7
8
9
10
11
12
Option ◀▶
Enter ◙
ECM Speed Info
1
2
G
3
Lo
4
5
▶
6
◀ Hi
7
8
9
10
11
12
Option ◀▶
Enter ◙
ECM Speed Info
1
2
G
3
Lo
4
5
6
Hi
7
8
9
▶10
◀ Aux
11
12
Option ◀▶
Enter ◙
ECM Speed Info
Blower Only Speed
3
Lo Compressor
6
Hi Compressor
9
Aux Heat
10
Want To Change?
Yes
Option ◀▶
No
Enter ◙
Cooling Airflow Setup
--- ECM Only ---
The airflow will be
adjusted by the chosen
amount in cooling mode.
Adjustment:
-15%
Want To Change?
Yes
Option ◀▶
No
Enter ◙
Cooling Airflow Setup
--- ECM Only ---
The airflow will be
adjusted by the chosen
amount in cooling mode.
Adjustment:
-15%
Change
▼▲
Enter ◙
Setting Blower Speed - Variable speed ECM
The ABC board’s Yellow Config LED will flash the current
ECM blower speed selections for G, low, and high
continuously with a short pause in between. The speeds
can also be confirmed with the AID Tool under the Setup/
ECM Setup screen. The Aux will not be flashed but can be
viewed in the AID Tool. The ECM blower motor speeds can
be field adjusted with or without using an AID Tool.
Variable speed ECM Setup without an AID Tool
The blower speeds for G only, Low (Y1), and High (Y2/
Aux) can be adjusted directly at the Aurora ABC board
which utilizes the push button (SW1) on the ABC board.
This procedure is outlined in the ECM Configuration Mode
portion of the Aurora ‘Base’ Control System section. The
Aux cannot be set manually without an AID Tool.
Variable speed ECM Setup with an AID Tool
A much easier method utilizes the AID Tool to change
the airflow using the procedure below. First navigate to
the Setup screen and then select ECM Setup. This screen
displays the current ECM settings. It allows the technician to
enter the setup screens to change the ECM settings. Change
the highlighted item using the
◄
and
► buttons and then press the
◙ button to select the item.
Selecting YES will enter ECM
speed setup, while selecting NO
will return to the previous screen.
ECM Speed Setup - These screens allow the technician to
select the G, low, high, and auxiliary heat blower speed for
the ECM blower motor. Change the highlighted item using
the
▲ and ▼ buttons. Press the ◙ button to select the speed.
After the auxiliary heat speed setting is selected the AID
Tool will automatically transfer back to the ECM Setup screen.
Cooling Airflow Setup - These screens allow the technician
to select -15%, -10%, -5%, None or +5% change from the
heating airflow. Change the adjustment percentage using
the
▲ and ▼ buttons. Press the ◙ button to save the change.
Variable Speed ECM Blower Motor
Model
Air Flow
Max ESP
(Pa)
Speed 1
Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12
009
124.50
135
179
G
248
L
319
385
463
519
576
628
680
H
727
Aux
743
009 w/746W*
186.75
227
267
G
314
L
359
411
472
519
566
614
665
H
717
Aux
769
012
186.75
224
293
G
345
L
401
481
538
599
661
717
779
H
845
Aux
908
015
186.75
189
283
G
392
L
496
580
661
736
802
883
949
H
1010
Aux
1069
**VS Compressor Speed
1-2
3-4
5-6
7-8
9-10
11-12
** VS Compressor speed is given for the factory default L/s settings. When the L/s default settings are changed it will change the
relationship to the compressor speed that is shown in the table. In cooling mode compressor speeds 10-12 are only available when
SuperBoost mode is selected at the thermostat.
* Optional 746W Variable Speed ECM
Factory settings are at recommended L , H and Aux positions
“G” may be located anywhere within the airflow table
“L” setting should be located within the boldface L/s range
“H” setting MUST be located within the shaded L/s range
“Aux” setting MUST be equal to or greater than “H” setting
“Aux” setting MUST be equal to or greater than the minimum allowable L/s for the auxiliary heater kit (see auxiliary heat ratings table)
Cfm is controlled within 5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter
5/13/13