StorCase Technology DS500 User Manual
Page 73

Appendix E SES/SAF-TE Host Connection
69
RemotaSilo User’s Guide - Rev. B00
Kingston Technology Company
Selecting the SCSI ID
The RemotaSilo’s SCSI ID number is determined by the first 3 jumper
settings (Jumper A, B, and C). See Figure E-2 for J3 pin assignments.
A
B
C
D
E
Jumper J3
SCSI Termination
Reserved
SCSI ID
0817
Figure E-2: J3 Jumper Settings
The Jumper J3 default setting (listed below in bold) is set to SCSI ID 6.
To change the SCSI ID, refer to Table E-1 to set the jumpers manually.
SCSI ID
Jumper A
Jumper B
Jumper C
0
Remove
Remove
Remove
1
Insert
Remove
Remove
2
Remove
Insert
Remove
3
Insert
Insert
Remove
4
Remove
Remove
Insert
5
Insert
Remove
Insert
6
Remove
Insert
Insert
7
Insert
Insert
Insert
Table E-1: SCSI ID Jumper Settings
SCSI Termination
The on-board SCSI terminator is enabled and disabled on Jumper J3
with the Jumper E setting (Pins 9 and 10) as shown in Table E-2. By
default, the factory-installed SCSI terminator is Disabled (Jumper E
inserted). Leave the jumper installed to disable onboard termination for
SES/SAF-TE configurations.