Appendix E SES/SAF-TE Host Connection

69

RemotaSilo User’s Guide - Rev. B00

Kingston Technology Company

Selecting the SCSI ID

The RemotaSilo’s SCSI ID number is determined by the first 3 jumper
settings (Jumper A, B, and C). See Figure E-2 for J3 pin assignments.

A

B

C

D

E

Jumper J3

SCSI Termination

Reserved

SCSI ID

0817

Figure E-2: J3 Jumper Settings

The Jumper J3 default setting (listed below in bold) is set to SCSI ID 6.
To change the SCSI ID, refer to Table E-1 to set the jumpers manually.

SCSI ID

Jumper A

Jumper B

Jumper C

0

Remove

Remove

Remove

1

Insert

Remove

Remove

2

Remove

Insert

Remove

3

Insert

Insert

Remove

4

Remove

Remove

Insert

5

Insert

Remove

Insert

6

Remove

Insert

Insert

7

Insert

Insert

Insert

Table E-1: SCSI ID Jumper Settings

SCSI Termination

The on-board SCSI terminator is enabled and disabled on Jumper J3
with the Jumper E setting (Pins 9 and 10) as shown in Table E-2. By
default, the factory-installed SCSI terminator is Disabled (Jumper E
inserted). Leave the jumper installed to disable onboard termination for
SES/SAF-TE configurations.