StorCase Technology DS500 User Manual
Page 45

Appendix C Software Features
41
RemotaSilo User’s Guide - Rev. B00
Kingston Technology Company
View / Chassis Monitor
This screen displays the detailed status for each RemotaSilo chassis
and may be accessed directly, or by selecting a specific Chassis ID
while in the View / Status Summary window. The title bar of this window
shows the RemotaSilo Chassis ID.
Time - displays the time of day according to the specified chassis’
internal clock. To synchronize the internal clock of each chassis with the
Host system clock, see the main menu Chassis / Set Clock command.
Temperature - displays the environmental temperature as measured
from inside the RemotaSilo chassis, in either degrees Celsius or
degrees Fahrenheit, depending the option selected from the Option /
Host Settings command from the main menu. If the temperature falls
within the defined warning temperature range, the displayed value will
be highlighted in yellow. If the temperature falls within the defined
alarm range, the displayed value will be highlighted in red. To set
warning and alarm temperature ranges, see main menu Chassis /
Temperature command.
Power Supply - displays the voltages measured from the +5V and
+12V chassis power suppl(ies). If these voltage measurements fall out
of the safe range, the corresponding value displayed will be highlighted
in red. The safe range for the +5V source is set from +4.75V to +5.25V;
the safe range for the +12V source is set from +11.35V to +12.65V. If a
power supply is not installed, N/I (for Not Installed) will be displayed.