Appendix C Software Features

Kingston Technology Company

RemotaSilo User’s Guide - Rev. B00

Advanced / Set Intervals

This command sets the time intervals at which the selected RemotaSilo
chassis regularly will receive status, check for existence of the Host
system connection, and to identify itself at power-on or reset. All
intervals are in seconds.

The Update value specifies the sampling period at which the
RemotaSilo circuit board receives voltage and temperature readings, as
well as operational status information for the DS500 fans, power
suppl(ies), and the installed RAID controller.

The Host check value specifies how frequently the circuit board on the
Master RemotaSilo chassis checks for the existence of the Host system
serial connection.

No host broadcast specifies how frequently each RemotaSilo Chassis
will identify itself while in Standalone mode. (See “Hardware
Description, Two Digit LED Display” section for Standalone Mode
description).

Select Apply to all RemotaSilo chassis to apply the displayed interval
values to all RemotaSilo chassis in the system.

Default button will set the following intervals:

Update = 5 seconds,
Host check = 15 seconds
No host broadcast = 5 seconds.

Click OK to save the interval settings.