42

Appendix C Software Features

Kingston Technology Company

RemotaSilo User’s Guide - Rev. B00

Drive - displays the voltages measured from the +5V and +12V
sources supplying power to the installed disk drives. If these voltage
measurements fall out of the safe range, the corresponding value
displayed will be highlighted in red. The safe range for the +5V source
is set from +4.75V to +5.25V; the safe range for the +12V source is set
from +11.35V to +12.65V.

Reference - displays the voltage measured from the +5V source
supplying power to the RemotaSilo circuit board. If this voltage falls out
of the safe range, the value displayed will be highlighted in red. The
safe range for the +5V source is set from +4.75V to +5.25V.

NOTE: The RemotaSilo circuitry requires that this voltage is accurate in
order to operate reliably. If this voltage falls out of the safe range, all
other voltage and temperature measurements will be invalid.

Fan Alarm - displays the operating status of all chassis fans: A, B, C,
and D. A checked box to the left of a specific fan ID indicates that the
fan has stopped or is not operating at full speed. For more about
DS500 Fan Alarms, see Chassis / Sound Control and the Chassis /

Reset Alarm main menu commands.

View / Drive Failure Summary

The Drive Failure Summary dialog lists locations of the drives which
have been identified as non-operational by the RAID controller.