8

9

SPECIFICATIONS

Range

0 to 2000 mS/cm (auto-ranging)

-30 to 130°C / -22 to 266°F

Resolution

1 μS/cm (0 to 1999 μS/cm)

0.01 mS/cm (2.00 to 19.99 mS/cm)

0.1 mS/cm (20.0 to 199.9 mS/cm)

1 mS/cm (200 to 2000 mS/cm)

0.1°C / 0.2°F

Accuracy

±2% f.s. (conductivity) / ±0.5°C / ±1°F

Typical EMC Deviation

±2% f.s. (conductivity) / ±0.5°C / ±1°F

Temp. Compensation

Automatic or manual, -30 to 130°C

Temperature Probe

3-wire or 2-wire Pt100 or Pt1000 sensor

with automatic recognition and damage test

Digital Input

Digital Transmitter, Hold & Advanced Cleaning inputs

Digital Output

1 digital insulated contact closed upon Hold mode

Analog Output

1 or 2 independent outputs;

0-22 mA (configuring as 0-20 mA or 4-20 mA)

Digital Serial Output

RS485

Dosing Relay

1, 2, 3 or 4 electromechanical relays SPDT;

5A-250 Vac, 5A-30 Vdc (resistive load);

fuse protected: 5A, 250 V fuse

Alarm Relay

1 electromechanical relay SPDT;

5A-250 Vac, 5A-30 Vdc (resistive load);

fuse protected: 5A, 250 V fuse

Installation Category

II

Power Supply

24 Vdc/ac, or

115 Vac or 230 Vac or 100 Vac ±10%, 50/60 Hz;

fuse protected: 400 mA, 250 V fast fuse

Power Consumption

10 VA

Max Oscillation Frequency

8 MHz

Environment

0 to 50°C (32 to 122°F); RH max 85% non-condensing

Enclosure

Single case 1/2 DIN

Weight

Approx. 1.6 kg (3.5 lb.)

The main features of the HI 720 controller series include:
• Measurement and control of conductivity or concentration
• Concentration can be measured as usual TDS (fixed ratio) or through custom

conductivity/temperature/concentration curves

• Customizing temperature coefficient table and NaCl temperature compensa-

tion according to IEC 746-3, in addition to the standard linear compensation

• Auto-ranging
• Display reading offset adjustment for temperature
• Temperature level alarm
• Cleaning in place activated through two cleaning commands, or triggered by

a variety of events

• Hold management, including a digital input to enter the hold mode through

an external trigger

• Conductivity probe check
• Digital transmitter input
• Pt100 or Pt1000 temperature sensor with automatic recognition and dam-

age test

• Calibration time-out
• Logging of the last 100 error, configuration and cleaning events
• Alarm fault current (3.6 mA or 22 mA)
• SMS messages sending
• Alarm configuration can be customized: different errors can lead different

actions (alarm relay activation, fault current, hold mode, automatic cleaning,
SMS message)

• RS485 communication with additional capabilities, such as error log file down-

loading and cleaning commands

• Daily programmable control timing
• Diagnostic features
• Password protection