14 replacement of parts – Glow-worm 24-38CXI Range User Manual
Page 46
46
0020013349-02
14.25 Filling Loop Tube
For access, refer to section 14.1.
Refer to section 12.10 and drain the boiler hot water circuit.
Refer to diagram 14.20.
Remove the retaining clips to remove the filling loop tube.
Fit new 'O' rings.
After replacing the filling loop tube open the cold-water isolation
valve and slowly open a hot water tap to remove air. Close the
hot water tap and check for any leaks.
14.26 Filling Loop Valve.
For access, refer to section 14.1.
Refer to section 12.10 and drain the boiler hot water circuit.
Refer to diagram 14.20.
Remove the clip securing the filling loop valve to the domestic
water filter housing. Disengage by pulling forward.
Remove the clip securing the filling loop to the filling loop valve.
Remove the filling loop valve from the filling loop.
Fit new 'O' rings.
After replacing the filling loop valve open the cold water isolation
valve and slowly open a hot water tap to remove air. Close the
hot water tap and check for any leaks.
14.27 Automatic Bypass Valve
For access, refer to section 14.1.
Refer to section 12.9 and drain the boiler heating circuit.
Refer to diagram 14.19.
Remove the retaining clip to remove the bypass valve.
Fit new 'O' rings.
Replace the bypass valve, refill, vent and pressurise the boiler.
Adjust the bypass as described in commissioning, see section
11.6.
Check for leaks.
14.28 Reduced Pressure Zone Valve
For access, refer to section 14.1.
Refer to diagram 14.21.
Refer to section 14.25 to remove the filling loop
Remove the retaining clip to remove the reduced pressure zone
valve.
Fit new 'O' rings.
Replace the reduced pressure zone valve, refill, vent and
pressurise the boiler.
Check for leaks.
14.29 Domestic Cold Water Inlet Filter
For access, refer to section 14.1.
Refer to section 12.7.
Fit new 'O' rings.
14 Replacement of Parts
Diagram 14.21
REDUCED
PRESSURE
ZONE
VALVE
11477
Diagram 14.20
FILLING LOOP
TUBE
FILLING LOOP
VALVE
RETAINING
CLIP
RETAINING
CLIPS
12945