beautypg.com

1 technical information, Table 1 – Glow-worm 24-38CXI Range User Manual

Page 11

background image

11

0020013349-02

24cxi

30cxi

38cxi

Lift Weight

41kg(90lb)

42kg(92.5lb) 44kg(97lb)

Total Weight (installed)

44kg(97lb)

45kg(99lb) 47kg(103.5lb)

● Gas connection

22mm copper

● Heating and return

22mm copper

● Domestic hot water

15mm copper

Safety valve

Preset 3bar (43.5lbf/in

2

)

Safety valve discharge

15mm copper

■ Expansion vessel capacity

8 litres (1.76 gallons)

Charge pressure

0.5bar (7.3lbf/in

2

)

Heating system

0.7bar (10.1lbf/in

2

)

minimum pressure

Max. Domestic hot water flow rate

at 35

O

C rise

24 cxi

9.8L/min.

30 cxi

12.3L/min.

38 cxi

15.5L/min.

Min. Domestic hot water flow rate

24/30/38cxi 1L/min.

Maximum flow temperature

63

0

C

Maximum heating system

130 litres

water content using

(28.6 gallons)

pressurised at 1bar.

fitted expansion vessel,
at 75

0

C average system

temperature

Electrical supply

230V~50Hz

Electrical rating

180W fused 3A

IP classification

X4D

Internal Fuse rating

On PCB

630mAT

TABLE 1

D.H.W Max. working pressure

10bar (145lbf/in

2

)

Minimum working pressure for
max. domestic flow rate

0.2bar (2.9lbf/in

2

)

1 Technical Information

Diagram 1.2

■ For larger systems use an additional

expansion vessel.

● Ball valves are fitted in water and gas connections.

12923