beautypg.com

Setting pass/fail thresholds – EXFO FPM-600 Power Meter User Manual

Page 37

background image

Measuring Power or Loss (FPM-600 and FOT-600)

Power Meter/Light Source/Optical Loss Test Set

31

Setting Pass/Fail Thresholds

Setting Pass/Fail Thresholds

You can define thresholds to specify acceptable power (dBm) or loss (dB)
values for each wavelength. Thresholds are often supplied by system
manufacturers and depend on the system deployed.

When a threshold is activated, the PASS/FAIL
LED is turned on. If it is green, the threshold
succeeded, if the PASS/FAIL LED is red, the
threshold failed.

To set pass/fail thresholds:
1.
From normal operating mode, press

repeatedly until you reach PM.

2. Press

to access the first submenu, then

press

repeatedly

until

you

reach

the

P/F

menu.

3. Press

to switch between power (dBm)

and loss (dB) values.

4. Press

to switch between available wavelengths. An asterisk (*)

appears beside activated thresholds. If no threshold is set for a
wavelength, the unit indicates “----”.

5. Press

to activate/deactivate the displayed threshold. The

PASS/FAIL LED will light (green or red) when you return to normal
mode.