Setting up your Unit

20

ETS-1000

Interface setup

Autoneg: enabling the auto-negotiation mode. If enabled, you need to
select the preferable rate (or set Automatic, any of the
10/100/1000Mbit/s values that can be used) and set the
Auto-negotiation parameter to On. The connection will be established
only if the auto-negotiation mode is enabled also on remote end, and
at least one of the parameters is set to the same value.

MAC address: MAC address of the port (A, B, or LAN), which can be
specified.

VLAN: Enabling/Disabling VLAN parameters setup.

ID: 12-bit VLAN identifier (integer in the range 0–4095).

Priority: traffic priority.

MPLS: switch to the MPLS. Interface A menu (MPLS. Interface B).

Note: if you use SFP-modules, then the Speed should be always set to the 1Gb/s

value.

Transmission: switch to the Label stack menu.

Reception: switch to the Reception rules menu.