Setting up your Unit

Ethernet Tester Analyzer

19

Interface setup

Interface setup

The Interface setup is used to configure the local test interface. The
required parameters correspond to the physical, data link, and network
layers. The parameters are globally configured and applied to all the tests
and tools. Ensure that these parameters are set before running any tests or
tools.

Configure the interface parameters from the Interface setup menu as
explained below.

Port: Select the Port to customize.

State: switch on/off the port. You can switch off unused port to save the
power.

Speed: select transmission rate. If you selected Automatic, then
transmission rate will be determined automatically (any of the
10/100/1000 Mbit/s values can be used). Also, in this case a value of the
Autoneg. Field will be set to On and become inaccessible.