Mportant, Updating analyzer software – EXFO ETS-1000 User Manual
Page 127

Remote Control
Ethernet Tester Analyzer
119
Management in the Terminal Mode
Updating Analyzer Software
Latest versions of the ETS-1000 software are available for downloading.
Current software versions are shown in the Information menu (ETS-1000
Settings >Information).
The order of update procedures for FPGA microcode and MCU program
does not matter. In addition, only one of those can be updated if there is no
new version for another one.
To update the FPGA:
1. Connect the ETS-1000 to PC via USB (see Terminal Mode Connection
Settings on page 117). Check the connection using AT command.
2. Enter ATR command. Select either system FPGA or expansion FPGA. In
the Transfer, send File menu of HyperTerminal utility, specify the path
to a FPGA microcode file (with .bin extension) in the Filename
window and select the Xmodem in the Protocol window. Click Send.
Estimated duration of the update procedure is 1 minute for the system
FPGA and 4 minutes for the Expansion FPGA. If the data displayed
previously on the screen has been restored, the update procedure is
completed successfully.
I
MPORTANT
False actions during the software update can lead to the unit part
malfunctioning which can be repaired in the service-center only.