Trouble shooting guide, Ducted evaporative air conditioning – Bonaire LV User Manual
Page 30

Multi-Appliance Manual Control
Ducted Evaporative Air Conditioning
TROUBLE SHOOTING GUIDE
PROBLEM
PROBABLE CAUSE
REMEDY
A
Black – out
a
Wait
b
Tripped Circuit Breaker
b
Reset
c
Blown Fuse
c
Replace
Unit fails to start
d
Electrical Fault
d
Call Climate Technologies
Service Provider
a
Pump Seized
a
Isolate power and then take
off top of pump and try to free
it. Some lubricant may help.
Pump fails to
start
b
Pump Burnt Out
b
Call Climate Technologies
Service Provider
a
Float Valve Leaking
a
Check adjustment or replace
seal
Water leaking
from overflow
b
Drain from Celdek Pads
b
Normal Operation
a
Loose Delivery Tube
a
Check and tighten
b
Break in tubing
b
Replace as necessary
Water Droplets in
air stream
c
Pump Delivers Excessive
Water to Pads
c
Adjust the Dialflo to reduce
the flow
a
Inadequate Relief
a
Provide more open area to
relieve stale air
Excessive
humidity
b
Outside humidity high
b
Turn pump off.
a
Dirty Filters
a
Clean / Replace
b
Dry Filters
b
Check water delivery system.
Adjust if necessary.
Inadequate
Cooling
c
Dialflo not set correctly
c
Adjust Dialflo so that the pads
have even saturation.
a
Unit located near odor source
a
Remove source
b
New Celdek filter smell
b
Smell will disappear after a
period of operation
(Approximately 48 hours or
use).
Unpleasant Odor
Rapid formation
of white deposits
on pads
High Mineral Content
Bleed off should be set at
maximum. More regular
maintenance may be required.
THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.
FOR SERVICE OR WARRANTY REQUIREMENTS PLEASE REFER
TO THE LAST PAGE OF THESE INSTRUCTIONS