Multi-Appliance Manual Control

Ducted Evaporative Air Conditioning

TROUBLE SHOOTING GUIDE

PROBLEM

PROBABLE CAUSE

REMEDY

A

Black – out

a

Wait

b

Tripped Circuit Breaker

b

Reset

c

Blown Fuse

c

Replace

Unit fails to start

d

Electrical Fault

d

Call Climate Technologies

Service Provider

a

Pump Seized

a

Isolate power and then take

off top of pump and try to free

it. Some lubricant may help.

Pump fails to

start

b

Pump Burnt Out

b

Call Climate Technologies

Service Provider

a

Float Valve Leaking

a

Check adjustment or replace

seal

Water leaking

from overflow

b

Drain from Celdek Pads

b

Normal Operation

a

Loose Delivery Tube

a

Check and tighten

b

Break in tubing

b

Replace as necessary

Water Droplets in

air stream

c

Pump Delivers Excessive

Water to Pads

c

Adjust the Dialflo to reduce

the flow

a

Inadequate Relief

a

Provide more open area to

relieve stale air

Excessive

humidity

b

Outside humidity high

b

Turn pump off.

a

Dirty Filters

a

Clean / Replace

b

Dry Filters

b

Check water delivery system.

Adjust if necessary.

Inadequate

Cooling

c

Dialflo not set correctly

c

Adjust Dialflo so that the pads

have even saturation.

a

Unit located near odor source

a

Remove source

b

New Celdek filter smell

b

Smell will disappear after a

period of operation

(Approximately 48 hours or

use).

Unpleasant Odor

Rapid formation

of white deposits

on pads

High Mineral Content

Bleed off should be set at

maximum. More regular

maintenance may be required.

THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.

FOR SERVICE OR WARRANTY REQUIREMENTS PLEASE REFER

TO THE LAST PAGE OF THESE INSTRUCTIONS