American Energy Systems Country Flame Little Rascal User Manual

Page 6

background image

6

combustion, such as occurs during start-up, shut down, or incorrect operation of the room heater will
lead to some soot formation which will collect in the exhaust venting system. The exhaust venting
system should be inspected at least once every year to determine if cleaning is necessary.

SPECIFICATIONS

FUEL TYPE:

A.P.F.I. residential fuel: Premium quality fuel only

Heat Content: 8200 BTU/lb. min.

Bulk Density: 40 lb. /cubic ft. min.

Moisture Content: 8% max

Ash Content: 1% max

Size:

¼”

to

5/16”

diameter

1.”

long

max

Fines: 1% max through 1/8

th

screen


HOPPER SIZE: 55pounds Hopper Capacity

FLUE SIZE:

3” or 4”

TYPE:

PL double wall vent with stainless steel inner liner


AIR INLET:

3” diameter (non-combustible) pipe (recommend double walled B-vent for fresh air only)


AUGER TYPE: Tumac 2 ¼ Auger Pellet Feed System

CONTROLS:

Integrated Feed Rate/Blower Speed Controls


ELECTRICAL: 120 Volts, 2.4 Amp, 60 Hz (always install an approved surge protector)

MEASUREMENTS:

UNIT BODY HEIGHT

22 ¾”

HEIGHT

ON

PEDESTAL

32

¾”

HEIGHT

ON

LEGS

31

1/4”

UNIT

WIDTH

26”

UNIT

DEPTH

19

3/4”

SHROUD

HEIGHT

29

7/8”

SHROUD

WIDTH

45

7/8”


CLEARANCES:

SIDES

1”

BACK

2”

TOP TO COMBUSTIBLE

3”

TOP TO CEILING

3”


*Combustible Flooring must be covered with non-combustible material extending 6” (150 mm) from front
of unit and 8” (205 mm) from unit on each side. The floor protection on the sides of the stove only has to
extend to the vertical sidewall(s) if the clearances are less than 8”.