beautypg.com

Set event receiver – ADLINK cPCI-6S10 User Manual

Page 42

background image

32

Hardware Platform Management

Response Data Fields

Set Event Receiver

Request Data Fields

Note: The commands “Set event receiver” and “Get event
receiver” are used for event delivery between IPMC and BMC.
Other address (except 0x20 to CMM by default) will cause incor-
rect behavior.

1

Completion Code
A management controller shall return an error Completion Code if an
attempt
is made to access an unsupported bus.
generic, plus following command specific codes:
81h = Lost Arbitration
82h = Bus Error
83h = NAK on Write
84h = Truncated Read

(2:M)

Bytes read from specified slave address. This field will be absent if the
read count is 0. The controller terminates the I 2 C transaction with a
STOP condition after reading the requested number of bytes.

ipmitool

ipmitool [parameters] raw 0x04 0x00 0x20 0x00

Terminal mode

[10 00 00 20 00]

Description

Set event receiver address, default event receiver is
0x20.

1

Slave address

2

[7:2] = reserved
[1:0] = Event receiver LUN