beautypg.com

Figure 2, Danger, Activating the bahery – Bolens 130-527-000 User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Screwdriver

FIGURE 1.

FIGURE 2.

DANGER

i

Battery contains sulfuric acid. Refer to warning on
page 6. Antidote: EXTERNAL—Flush with water.
INTERNAL—Drink large quantities of water or milk.
Follow with milk of magnesia, beaten eggs or vegetable
oil. Call physician immediately. EYES: Flush with cool

water for at least 15 minutes, then get prompt medical

attention.

Since batteries produce explosive gases, keep all
lighted materials (cigarettes, lighters, matches, etc.)
away. Be sure to charge battery only in well-ventilated
areas. Make certain venting path of battery (drain tube)
is always open.

KEEP BATTERIES

OUT OF THE REACH OF CHILDREN!

ACTIVATING THE BAHERY

Do not activate battery (fill with battery acid) until
battery is actually placed in service. Be certain to
read previous warnings before activating the
battery.

1. Open the battery pack. Be careful not to puncture

the box. It contains the battery with a long plastic
tube attached, battery fluid (acid) in a plastic con­
tainer, one short plastic tube and one hardware
pack (two hex bolts and nuts).

2. Place the battery on a table or workbench. Make

certain the long plastic drain tube is in place on
the vent elbow.

3. Remove the six fill caps from the top of the bat­

tery with a screwdriver. Be careful not to damage

----- the fill caps. See figure 1.

4. Place the battery fluid container on the table or

workbench. Carefully cut off tip of the spout and
attach the short plastic tube provided. Do not
squeeze the container when cutting tip.

5. Fill each battery cell slowly and carefully to the UP-

---- PER LEVEL line marked on battery. See figure 2.

Use caution as the acid level will rise rapidly after

the bottom of the cell is filled.

6. Allow battery to stand for 30 minutes with the fill

caps removed, while the plates absorb acid.

7. If acid level has fallen after the 30 minute standing

period, refill each cell with battery acid to the UP­
PER LEVEL line on battery. Replace the fill caps.

8. Before discarding the empty container, neutralize

any residue with baking soda and rinse container
with water. Puncture container several times
before discarding.

9. Charge the battery after the 30 minute standing

period. SLOW CHARGE THE BATTERY (DO NOT
FAST CHARGE) at a maximum bench rate of 1.4
amperes until the specific gravity reading is
1.260-1.280. Charge for a minimum of 2 hours and
a maximum of 8 hours.

NOTE: Charging rate after battery has been put into

operation: The battery is to be charged for a period of

14-16 hours. NO LONGER THAN 30 HOURS.

After battery has been charged, add oniy distilled water.

Do not add acid.

NOTE: During normal operation, it is only necessary to
charge the battery:

1. When it is activated for the first time.

2. Before winter storage.
3. Before using the lawn tractor after winter storage.