beautypg.com

Citizen Systems CBM-253 User Manual

Page 82

background image

CBM-253 User’s Manual

70

CITIZEN

ESC v

[Name]

Sending of the printer status (only Serial interface)

[Code]

<1B>H <76>H

[Function]

Sends the status of the printer at the current point of time.

[Items requiring caution]

The status that is sent will be 1 byte of data, and the contents will be as shown in the table

below. When the control is set to DTR/DSR, 1 byte only should be sent after confirming

that the host is in the receiving possible condition (the DSR signal is at 'space'). Further,

when the control is set to XON/XOFF, one byte only should be sent without confirming

the DSR signal condition.

When the control is set to DTR/DSR and the host is in the receiving not possible

condition (the DSR signal is at 'mark'), wait until the DSR signal is in the receiving

possible condition. In the paper end (paper near-end) condition, there may be instances in

which receiving of this command may not be possible due to the BUSY condition.

This command will only be effective in serial interface printers .

Bit Function

0

1

0

Paper near-end

Paper present

No paper

1

Not defined

2

Paper end

Paper present

No paper

3

Not defined

4

Not used

Fixed at 0

5

Not defined

6

Not defined

7

Not defined