[Items requiring caution]

When this command has been executed, the internal counter that counts the number of

repetitions while the counter value remains fixed will be cleared.

It will be possible to omit any of the N1~N5 values. In this situation, the values of the

omitted parameters will not be changed and will remain set at their previous values.

For each of the N1~N5 values it is forbidden to include characters that are not '0'~'9'.

If an incorrect format is used, this parameter setting will be invalid, and the following

data will be processed as ordinary data.

When counting up:

When the result of the counting up exceeds the maximum value, the counting up will

start counting from the minimum value once again.

When the counter value set using N5 is outside the operating range of the counter, the

counter will be forcibly changed to the minimum value by the execution of GS c.

When counting down:

When the result of the counting down becomes smaller than the minimum value, the

counting down will start counting from the maximum value once again.

When the counter value set using N5 is outside the operating range of the counter, the

counter will be forcibly changed to the maximum value by the execution of GS c.

[Initial value]

N1 = 1, N2 = 65535, N3 = l, N4 = l, N5 = 1

[Reference]

GS C 0, GS C 1, GS C 2, GS c