10 scheduler – Winco DSE7300 Series User Manual
Page 95
![background image](/manuals/716100/95/background.png)
DSE Model 7000 Series Control & Instrumentation System Operators Manual
Part No. 057-074 7000 Series OPERATING MANUAL ISSUE 5 15/10/2009 ADM
95
8.10 SCHEDULER
DSE7000 Series contains an inbuilt exercise run scheduler, capable of automatically starting and stopping the set.
Up to 16 scheduled start/stop sequences can be configured to repeat on a 7-day or 28-day cycle.
Scheduled runs may be on load or off load depending upon module configuration.
Example
Screen capture from DSE Configuration Suite
Software showing the configuration of the Exercise
Scheduler.
In this example the set will start at 09:00 on Monday
and run for 5 hours, then start at 13:30 on Tuesday
and run for 30 minutes.
8.10.1 STOP MODE
•
Scheduled runs will not occur when the module is in STOP/RESET mode.
8.10.2 MANUAL MODE
•
Scheduled runs will not occur when the module is in MANUAL mode.
•
Activation of a Scheduled Run ‘On Load’ when the module is operating OFF LOAD in Manual mode will
have no effect, the set continues to run OFF LOAD
8.10.3 AUTO MODE
•
Scheduled runs will operate ONLY if the module is in AUTO mode with no Shutdown or Electrical Trip alarm
present.
•
If the module is in STOP or MANUAL mode when a scheduled run begins, the engine will not be started.
However, if the module is moved into AUTO mode during a scheduled run, the engine will be called to start.
•
Depending upon configuration by the system designer, an external input can be used to inhibit a scheduled
run.
•
If the engine is running OFF LOAD in AUTO mode and a scheduled run configured to ‘On Load’ begins, the
set is placed ON LOAD for the duration of the Schedule.