Example 1 continued – Modem diagnostics
NOTE:- Modem diagnostic screens are available on 73xx module versions 5 and above only. The
modem screens appear only when the module has been configured for use with a modem.
Modem diagnostic screens are included; press
when viewing the Serial Port instrument to cycle the available
screens. If you are experiencing modem communication problems, this information will aid troubleshooting.
Line
Description
RTS
Request To Send
Flow control
CTS
Clear To Send
Flow control
DSR
Data Set Ready
Ready to communicate
DTR
Data Terminal Ready
Ready to communicate
DCD
Data Carrier Detect
Modem is connected
Shows the state of the modem communication lines. These can help
diagnose connection problems.
Example :
RTS
A dark background shows the line is active.
RTS
a grey background shows that the line is toggling high and low.
RTS No background indicates that the line is inactive
Shows the last command sent to the modem and the result of the