XDV Direct Vent Gas Fireplace

16

10009383

DVR584-600
Rear vent no elbows
2/99 djt

20"

(508 mm)

Rear Vent Top View

DVR584-600

Fig. 21 Rear vent application, no elbows.

FP836

Rear Vent-Top View

11/21/98

20"

(508 mm)

Max.

REAR VENT-TOP VIEW

20"

(508 mm)

Max.

45°

45°

FP836

Fig. 22 Rear vent application, one 45° elbow.

Rear Wall Installation

Twist Lock Pipe

STEP 1
Locate vent opening on the wall. To locate hole center
consult with appropriate fireplace dimensions, Page 4.
Frame as shown below.
NOTE: When using flex vent, the opening will have to
be measured according to the 1/2” (13 mm) rise in 12”
(305 mm) vertical run.
Combustible Walls (Fig. 23): Cut a 10³⁄₈”H x 9³⁄₈” W
(264 x 240 mm) hole through the exterior wall and
frame as shown.
Noncombustible Walls (Fig. 23): Hole opening must
be 7¹⁄₂” (190 mm) in diameter.

Zero clearance sleeve is only required for
combustible walls.

STEP 2
Measure wall thickness and cut zero clearance sleeve
parts to proper length (MAXIMUM 12”/305 mm). Assem-
ble sleeve and attach to firestop with #8 sheet metal
screws (supplied). (Fig. 24)
STEP 3
Measure the horizontal length requirement for the vent-
ing including a 2” (51 mm) overlap, i.e. from the elbow
to the outside wall face plus 2” (51 mm). (Fig. 22)

VO584-100
Vent Opening
2/99 djt

Vent Opening for Combustible Wall

9³⁄₈”

(240mm)

10³⁄₈”

(264mm)

Fireplace Hearth

Framing

Detail

Opening for Noncombustible Wall

7¹⁄₂”

(190 mm)

VO584-100

Fig. 23 Locate vent opening on wall.

ZCS101
Zero Clearance Sleeve
3/11/99 djt

Max. Length

12” (305mm)

#8 Screws (2)

#8 Screws

(2)

Adjustable
Zero Clearance
Sleeve

#8

Screws

(2)

Adjustable Zero Clearance Sleeve

ZCS101

Fig. 24 Adjustable zero clearance sleeve.

Firestop

STEP 4
Install the 4” (102 mm) vent to the appliance collar and
secure with three (3) sheet metal screws. Install the 7”
(178 mm) vent pipe tot he appliance collar and secure
with three (3) sheet metal screws. It is not necessary
to seal this connection. If a 45° elbow is being used,
attach the elbow to the appliance in the same manner
then attach the venting to the elbow.

It is critical there is no downward slope
away from the appliance when connecting
the vent or elbow.

STEP 5
Guide the venting through the vent hole a you place the
appliance in its installed position. Guide the 4” (102 mm)
and 7” (178 mm) collar of the vent termination into the
outer ends of the venting. Do not force the termination. If
the vent pipes do not align with the termination, remove
and realign the venting at the appliance flue collars.
(Fig. 25) Attach the termination to the wall as outlined in
the instruction sheet supplied with the termination.