beautypg.com

Wiring – Toa TS-910 Series Installation User Manual

Page 44

background image

44

• There is restriction on the number of the Bridge units that can be connected to one of the Expansion unit’s

Bridge unit connection terminals. (Refer to p. 42.)

Expansion unit TS-918

Bridge unit

TS-919B4

Bridge unit

TS-919B1

Conference unit TS-911/912/811/812

Coaxial cable

LAN cable (CAT-5)

BRIDGE UNIT

EXPANSION

TS-919B4

BRIDGE

1

2

3

4

BRIDGE UNIT

EXPANSION

TS-919B4

BRIDGE

1

2

3

4

1

TS-919B1

EXPANSION

BRIDGE

BRIDGE UNIT

7.3. Wiring

7.3.1. Type of cable used

Connection

Cable

Between the Central unit and the

Expansion unit

Coaxial cable Use one of the following types: RG-59/U, RG-6/U,

and RG-11/U.

Between the Expansion unit and

the Wired Conference units

LAN cable

Use LAN cables that are compatible with UTP Category

5 (straight cable) or that can support transmission

speeds exceeding that of Category 5 cable.

Note

Cable lengths for the above wiring need not be adjusted as required in the case of the Infrared Transmitter/

Receiver unit.

7.3.2. Extendable cable distances

The extendable distance differs depending on whether or not a Distributor is used.

[When using the Distributor (Maximum cable distance: 100 m)]

Distance between the Central unit and each Wired Conference unit: 100 m* max.

* Total distance of coaxial cable and LAN cable.

There is no restriction on the ratio of the cable length between the two.

Central unit

TS-910

Bridge unit

TS-919B4

Bridge unit TS-919B1

Expansion unit TS-918

Maximum 100 m

Distributor YW-1022

(2 branches) or

YW-1024 (4 branches)

Coaxial cable

LAN cable (CAT-5)

Wired Conference unit

TS-911/912/811/812