Wired conference unit connection, Central unit and expansion unit connection – Toa TS-910 Series Installation User Manual
Page 39

39
7. WIRED CONFERENCE UNIT CONNECTION
When connecting the Wired Conference units to the Central unit, the Expansion unit and the Bridge unit must
be installed between them.
Central unit TS-910
Expansion unit TS-918
Bridge unit
TS-919B1/919B4
Wired Conference unit
TS-911/912/811/812
1
TS-919B1
EXPANSION
BRIDGE
BRIDGE UNIT
Coaxial cable
LAN cable (CAT-5)
Central unit TS-910 (Rear)
Expansion unit TS-918
Coaxial cable
LAN cable (CAT-5)
Central unit TS-910
Expansion unit TS-918
Expansion unit TS-918
Distributor YW-1022
(2 branches)
Coaxial cable
7.1. Central Unit and Expansion Unit Connection
Use a coaxial cable to connect the Expansion unit to the Central unit’s Infrared Transmitter/Receiver input/
output terminal.
One Expansion unit can be connected per Infrared Transmitter/Receiver input/output terminal.
When connecting 2 – 4 Expansion units to a single Infrared Transmitter/Receiver input/output terminal, follow
the instructions below.
7.1.1. Connecting 2 Expansion units
Make connections as follows using the YW-1022 Distributor (2-branch distribution).