Straight implement type, Fieldware, Link 4.02 – TeeJet Fieldware Link User Manual
Page 20

16
www.teejet.com
Fieldware
®
Link 4.02
ABSC Enabled – Smartcable or Section Driver
Module Setup
Smartcable or Section Driver Module setup is used when a Smartcable
or Section Driver Module (SDM) is on the system. The boom or delivery
area can be entered as up to 15 sections. Each section can vary in
width and in spreader mode, can vary in length. Additional options
available with a SDM include application overlap, application delay and
staggered mode.
NOTE: If a Smartcable or Section Driver Module (SDM) is not present,
refer to “Single Section Setup” to view setup steps.
Straight Implement Type
NOTE: When loading this profile type onto a console without a
Smartcable or SDM on the system, only values for Section 1
will be used. All other section or ABSC information will be
retained in the background as unused parts of the profile.
Basic Properties
►Description – used to enter the name of the Machine Settings
profile.
►GPS Antenna Height – used to measure the height of the
antenna from the ground. Range is 0.0 to 32.81 feet /
0.0 to 10.0 meters.
►Guidance Width – used to enter the distance between the
guidelines. Range is 3.28 to 246.06 feet / 1.0 to 75.0 meters.
►Implement Type – used to select
Straight
as the layout of the
sections for the applied product location.
►Implement Offset Direction
– direction from the centerline of
the machine to the center of the implement while facing in the
machine’s forward direction
►Implement Offset Distance
– used to enter the distance from
the centerline of the machine to the center of the implement.
Range is 0.0 to 32.81 feet / 0.0 to 10.0 meters.
►Boom Offset Direction – used to select whether the boom is
located in front of or behind the GPS antenna as the vehicle
moves in a forward direction
►Antenna to Boom Distance
– used to enter the distance from
the GPS antenna to the boom. Range is 0.0 to 164.04 feet /
0.0 to 50.0 meters.
►Number of Implement Sections – used to select the number
of implement sections. When ABSC Enabled is checked,
Smartcable and SDM options are available for editing.
►Tank Capacity – used to enter the capacity of the tank
►ABSC Enabled – used to enable ABSC (Automatic Boom
Section Control) options
• Unchecked – single section setup options will be available
(see “ABSC Enabled – Single Section Setup” section for
details)
• Checked – Smartcable or SDM setup options will be available
Implement Dynamics
►Delay On Time – used to set the time when each section will
switch on when entering an area that has not been applied. If
the application turns on too soon when entering an unapplied
area, decrease the delay on time. If the application turns on too
late, increase the delay on time. Range is 0 to 10 seconds.
►Delay Off Time – used to set the time when each section will
switch off when entering an area that has been applied. If the
application turns off too soon when entering an applied area,
decrease the delay off time. If the application turns off too late,
increase the delay off time. Range is 0 to 10 seconds.
►Section Width (under Spray Width in Matrix Pro v2.xx
or Matrix Pro GS v2.xx, or under Application width in
Matrix Pro GS v3.xx) – used to enter the width of each section of
the implement. Each section can be a different width. Sections
are numbered from left to right while facing in the machine’s
forward direction. Range for each section is 0.0 to 246.06 feet/
0.0 to 75.0 meters. Total for all sections must be greater than
3.28 feet / 1.0 meters.
Job Specific Defaults
►Overlap – used to select the amount of overlap allowed when
the sections are turned on and off while using automatic boom
section control
Figure 37: Basic Properties
Figure 38: Implement Offset Distance and Direction