Staggered implement type, Fieldware, Link 4.02 – TeeJet Fieldware Link User Manual
Page 19

15
98-05244-ENUS R1
Fieldware
®
Link 4.02
Staggered Implement Type
NOTE: This profile type will be loaded on to the console as “Straight”.
Basic Properties
►Description – used to enter the name of the Machine Settings
profile.
►GPS Antenna Height – used to measure the height of the
antenna from the ground. Range is 0.0 to 32.81 feet / 0.0 to
10.0 meters.
►Guidance Width – used to enter the distance between the
guidelines. Range is 3.28 to 246.06 feet / 1.0 to 75.0 meters.
►Implement Type – used to select
Staggered
as the layout of
the sections for the applied product location.
►Implement Offset Direction
– direction from the centerline of
the machine to the center of the implement while facing in the
machine’s forward direction
►Implement Offset Distance
– used to enter the distance from
the centerline of the machine to the center of the implement.
Range is 0.0 to 32.81 feet / 0.0 to 10.0 meters.
►Section 1 Offset Direction – used to select whether section 1
is located in front of or behind the GPS antenna as the vehicle
moves in a forward direction
►Antenna to Section 1 Distance
– used to enter the distance
from the GPS antenna to the section 1. Range is 0.0 to
164.04 feet / 0.0 to 50.0 meters.
►Number of Implement Sections – used to select the number
of implement sections. When ABSC Enabled is unchecked,
Number of Implement Sections is set to one implement section
and is unavailable for editing.
►Tank Capacity – used to enter the capacity of the tank
►ABSC Enabled – used to enable ABSC (Automatic Boom
Section Control) options
• Unchecked – single section setup options will be available
• Checked – Smartcable or SDM setup options will be available
(see “ABSC Enabled – Smartcable or Section Driver Module
Setup” section for details)
Implement Dynamics
►Section Width (under Spray Width in Matrix Pro v2.xx
or Matrix Pro GS v2.xx, or under Application width in
Matrix Pro GS v3.xx) – used to enter the total width of the
implement.
Job Specific Defaults
There are no available options.
Figure 34: Basic Properties
Figure 35: Implement Offset Distance and Direction
Figure 36: Machine Settings – Staggered Implement Type