OVER

VIE
W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

►Reference Gate Height – used to establish the actual gate height used during the calibration process
►Delete Total Counters – used to clear the Total Count system counter for Area, Volume and Time

NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save

the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous

menu.

USER INTERFACE

User Interface allows the operator to select the system virtual terminal (VT) if more than one VT is available on the

ISOBUS CAN.

MAIN SETUP MODE MENU STRUCTURE

|

|

|

|

|

|

Counters

Job Parameters

Machine

User Interface

Communication

Help

1. From the Main Setup Screen ,

Figure 3-28: User Interface

select USER INTERFACE.

NOTE: Settings are NOT automatically saved when

selected. The ACCEPT KEY must be selected

to save the setting. Select the ESCAPE KEY

to escape without saving settings and return to the

previous menu.

Use Preferred VT

Use Preferred VT sets the virtual terminal preference to

either on or off. If “On” is selected, the preferred VT will

be used. If “Off” is selected, the system will arbitrarily

select which VT to use (if more than one VT is available

on the ISOBUS CAN).
NOTE: This should always be set to "off" unless another VT is on the CAN bus.

• To set the Use Preferred VT mode, select an option from the drop down menu or use the UP/DOWN

ARROWS to highlight the option.