Implement parameters, Working width, Fast empty bed rpm – TeeJet IC18 SPREADER JOB COMPUTER User Manual
Page 28: Master switch, Isobus job computer : ic18 spreader na

23
98-05173 R1 US
ISOBUS Job Computer : IC18 Spreader NA
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
Implement Parameters
Figure 3-18: Implement parameters
Figure 3-19: Fast Empty Key
Implement Parameters establishes the the Working Width,
Fast Empty Bed RPM and Master Switch location.
Working Width
Working Width establishes the desired distance between
each adjacent pass while spreading.
• To select the Working Width, use the number pad or
slide bar.
Fast Empty Bed RPM
Fast Empty Bed RPM establishes the revolutions per
minute of the roller used to drive the conveyor during the
Fast Empty.
• To select the RPM, use the number pad or slide bar.
The availability of Fast Empty is established in the OEM
menu under Program Modes. When set to "On", the Fast
Empty Key will be available on the Home Screen.
Master Switch
Master Switch is used to allow the operator to choose
between a “remote master” switch or the Start/Stop Key.
• To select the Master Switch, select an option
from the drop down menu or use the UP/DOWN
ARROWS to highlight the option.