beautypg.com

Implement parameters, Working width, Fast empty bed rpm – TeeJet IC18 SPREADER JOB COMPUTER User Manual

Page 28: Master switch, Isobus job computer : ic18 spreader na

background image

23

98-05173 R1 US

ISOBUS Job Computer : IC18 Spreader NA

OVER

VIE

W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

Implement Parameters

Figure 3-18: Implement parameters

Figure 3-19: Fast Empty Key

Implement Parameters establishes the the Working Width,

Fast Empty Bed RPM and Master Switch location.

Working Width

Working Width establishes the desired distance between

each adjacent pass while spreading.

• To select the Working Width, use the number pad or

slide bar.

Fast Empty Bed RPM

Fast Empty Bed RPM establishes the revolutions per

minute of the roller used to drive the conveyor during the

Fast Empty.

• To select the RPM, use the number pad or slide bar.

The availability of Fast Empty is established in the OEM

menu under Program Modes. When set to "On", the Fast

Empty Key will be available on the Home Screen.

Master Switch

Master Switch is used to allow the operator to choose

between a “remote master” switch or the Start/Stop Key.

• To select the Master Switch, select an option

from the drop down menu or use the UP/DOWN

ARROWS to highlight the option.