Figure 3-35 ), Figure 3-35: removing interface/lvs module – PRG Bad Boy Field Service Manual User Manual
Page 81

BAD BOY
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
73
Figure 3-35: Removing Interface/LVS Module
6
7
8
CN3
LVS DETAIL
N
L
POWERCON
GND
WHITE
BLACK
GRN/YEL
GND
LVS
GND
N
BLK
WHT
N
WHT
BLK
GND
Fan
Fan
CAN Bus
Low Voltage DC Output
AC Line Input
L
CN1
N
2
1
3
4
5
FA
N
1
RED
BLACK
10-32 x 3/8" PPB
SEMS Screw (4)
Interface/LVS Module
Enclosure
Power Cables:
Do not disconnect cables
from positions 4 & 5