Once the system has been hung, cabled and connected to the console via the control snake:
Step 1. Apply power to DMX200 unit. Verify that on switch lights.
Step 2. Verify that console is powered up and patched.
Step 3. Verify that red and green LEDs on DMX200 unit are blinking on and off. If they are not, at
XLR input connector, verify that cable is correctly installed and fully seated.
Step 4. Verify seven segment display on DMX200 unit matches DMX512 connections:
Display readout "1" = connection to DMX IN #1
Display readout "2" = connection to DMX IN #2
Display readout "3" = connection to DMX IN #1 & 2
Display readout "n" = no DMX IN connection
Step 5. Apply power to lights at ACS rack.
Step 6. Watch luminaires calibrate. Be aware that luminaires will only calibrate if a valid if
operating system is received from the DMX200 unit.
Step 7. Tilt all luminaires parallel to the floor and start all lamps if not already struck.
Step 8. For luminaires that do not light, try to start lamp again. If luminaire still does not light,
problem may be in lamp or connections to lamp. Refer to appropriate luminaire user’s
manual for troubleshooting procedures.
Step 9. Perform visual check of the system. Note any lamps that have not started or appear dim or
discolored.
a. If lamp appears unusually dim after three minutes, douse lamp, wait five minutes, and
recheck lamp mounting. Ensure that lamp is securely seated in its socket and oriented
properly. Unusually dim luminaires may need to have lamp replaced. Refer to
appropriate luminaire user’s manual for lamp replacement procedure.
b. If any lamps still do not start, replace it. If new lamp does not start, problem may be
power supply.
Step 10. Perform diagnostic cues for each luminaire.