Test Software/Test Tables
The following tables contain test software test numbers, parameters, error codes, and comments. Use
these tables to run luminaire tests.
Note: Test numbers not listed are not valid.
CAUTION: Tests should not be run for more than 30 seconds, as this can further damage the
luminaire. Any tests run at FULL SPEED should not be run for more than 15 seconds.
Table 4-1: VL5 Family Mechanical Tests
Test Number
Test Parameter
Error Codes/Comments
000
Start Test
9
End Stop (Open)
001
Pan Test
8
End Stop (Clsd)
103
No Reset (Pan)
002
Tilt Test
7
Speed 1 (25%)
203
No Reset (Tilt)
004
Diffuser Test
6
Speed 2 (35%)
104
No Change (Pan)
005
Intensity Test
(VL5Arc Only)
5
Speed 3 (45%)
204
No Change (Tilt)
4
Speed 4 (55%)
006
Blue Filter Test
3
Speed 5 (65%)
007
Amber Filter Test
2
Speed 6 (75%)
008
Magenta Filter Test
1
Speed 7 (85%)
0
Speed 8 (Full Speed)
012
All Motors
(synchronized)
013
All Motors
(unsynchronized)
912
End Motor
(in calibration position)
Table 4-2: VL5 Family Default Programs
Test Number
Test
Functions
31
Pan and Tilt
701
Pan 25% Speed
702
Tilt 25% Speed
37
VL5 Functions
704
Edge 25% Speed
706
Blue Filter Test 25% Speed
707
Amber Filter Test 25% Speed
708
Magenta Filter Test 25% Speed