beautypg.com

Series 200 luminaires, Connecting to system, Dmx512 r – PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual

Page 88: Refer also to "dmx512 system example" on page 7

background image

DMX512 R

EFERENCE

G

UIDE

8 0

02.3004.0300.54

Series 200 Luminaires

Refer also to

"DMX512 System Example" on page 7

.

Connecting to System

Series 200 luminaires will require a DMX200 interface unit in order to control them from DMX512
consoles.

Step 1. Locate house AC service.

a. Determine location of main power service where lighting system will be connected.
b. Verify with a qualified electrician (see WARNING above) that house AC service is

within system operating voltages: 85 - 130 VAC or 170 - 260 VAC, single or three
phase, 50 or 60 Hz. Ensure that house service can accommodate connecting 2/0 pig tails
or 8/5 cables to house service lugs.

Step 2. Position ACS, Mini-ACS, or SixPack chassis delta/we switches to correct setting.

Refer to

"Configuring Equipment For Delta or Wye Operation" on page 20

.

Step 3. Tie in 2/0 or 8/5 tails.

a. Remove power from house service or verify that service disconnect switch is in the OFF

position.

b. Have a qualified electrician connect 2/0 or 8/5 pig tails to house service.

DMX200 Translator

Y Cable

INP

U

T

ACS Rack

OUT

P

UT

INPUT

OUTPUT

Series 200

Lamp Cable

Data & Power

Series 200

Trunk Cable

Data & Power

Series 200 luminaires

VL2B/VL2C, VL4

DMX200 Unit

S200

Repeater

Data & Power

XLR DMX Data Cable
from DMX512 source.

Power from
Modular Rack