Cable/connector terminology – PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual
Page 11

I
NTRODUCTION
0 2. 3 0 0 4. 0 3 00 . 5 4
3
Cable/Connector Terminology
This manual uses American wire gauge (AWG) measurements when describing cables and connectors.
For use in countries outside the U.S., or for assembling compatible cables, consult the AWG/Metric
Conversion Table given below for the appropriate metric equivalent.
CAUTION: Although maximum rated currents are 225A and 35A, we recommend that continuous
operating current does not exceed 150A and 20A respectively.
Other common terms used when describing cables and/or connectors are as follows:
European mains cable sizes [single core rubber insulation (HO-7RN-F)] are measured in cross-
sectional square millimeters. Commonly available sizes are 35 mm
2
(
∼150 Amp), 70 mm
2
(
∼250
Amp), and 95 mm
2
(
∼300 Amp).
AWG
Metric
Max Rated Current
2/0
67.5 mm
2
225A
8/5
8.37 mm
2
(5 x 6.0 mm
2
)
35A
Term
Definition
plug
male connector
receptacle
Female connector
Hubbell
®
connector
five-pin, three phase connector (8/5)
Epic
®
connector
six-pin, three phase connector (8/5)
Cam-Lok
®
connector