PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual
Page 114

DMX512 R
EFERENCE
G
UIDE
1 0 6
02.3004.0300.54
5
Plate cycles full travel at 100% speed
along Y vector
(Test Type 67C)
4
Type 67B, 25% speed
3
Type 67B, 50% speed
2
Type 67B, 75% speed
1
Plate cycles full travel at 100% speed
along X vector
(Test Type 67B)
0
Plate moves from X & Y EOT to oppo-
site X & Y EOT syncronous, repeatedly
at 100% speed
(Test Type 67A)
008
Fixed Gobo
9
Cycle from index 0 to index 1 CW, and
from index 1 to index 0 CCW repeat-
edly. Pause briefly on index 0 and 1.
(Test Type 8F)
8
Cycle from index 0 to index 11 CCW,
and from index 11 to index 0 CW
repeatedly. Pause briefly on index 0
and 11. (Test Type 8E)
7
Cycle from index 0 to index 6 CW, and
from index 6 to index 0 CCW repeat-
edly. Pause briefly on index 0 and 6.
(Test Type 8D)
6
Cycle from index 0 to index 6 CCW,
and from index 6 to index 0 CW repeat-
edly. Pause briefly on index 0 and 6.
(Test Type 8C)
5
Continuously index CW to next gobo
position on wheel (from 2 to 3, from 11
to 0). Pause briefly on each gobo. (Test
Type 8B)
4
Type 8A, 20% speed
3
Type 8A, 40% speed
2
Type 8A, 60% speed
1
Type 8A, 80% speed
0
Wheel spins CW at 100% speed (Test
Type 8A)
009
Rotating Gobo
9
Cycle from index 0 to index 1 CW, and
from index 1 to index 0 CCW repeat-
edly. Pause briefly on index 0 and 1.
(Test Type 9G)
8
Cycle from index 0 to index 5 CCW,
and from index 5 to index 0 CW repeat-
edly. Pause briefly on index 0 and 5.
(Test Type 9F)
Table 4-7: VL7/VL7U Mechanical Tests (Continued)
Test Number
Test Parameter
Error Codes/Comments